FIRE PROTECTION
- TOTALPAC® 3
The Legendary TOTALPAC 3
Designed with user-friendly features, the TOTALPAC® 3 units are easy to install and maintain. Compact and aesthetic, this system set the bar for modern fire protection applications.
Benefits of the TOTALPAC 3 Units
Designed with user-friendly features, the TOTALPAC® 3 units are easy to install and maintain.
The Cabinet
Factory assembly of the TOTALPAC® 3 cabinets ensures that all components have been carefully integrated. All systems are fully programmed and tested at the factory which facilitates the onsite installation and commissioning process.
The FireFlex® cabinets are of the freestanding type and are made of robust 14 gauge steel with a corrosion resistant fire red paint finish, polyester powder-coated and oven-baked on a phosphate base. Cabinets are also provided with two locked frontal doors that are removable without special tools, reducing space requirements for ease of installation and maintenance. Furthermore, all doors are provided with a neoprene gasket to reduce vibrations.
Technical details:
- FM and cULus Approved as a factory assembled unit
- Modular releases (manual, fail-safe, electric & pneumatic)
- Compact layout saves floor space
- Fully tested and programmed at the factory
- Unique serial number on every unit
- Simplified operation and maintenance
- Factory built under ISO-9001 conditions
Quality Parts & Flexibility
Remote-controlled Preassembled Unit
The unit is provided with a junction box atop the sprinkler trim enclosure where all internal devices are prewired to a sturdy set of terminals for field wiring to a releasing control panel to be provided by others.
Self-contained Preassembled Unit
Optional Self-contained unit prewired to the Viking VFR-400 releasing control panel installed in an enclosure atop the sprinkler trim enclosure.
Modular Release Trim
Units are built from subassemblies using quality pipe unions making servicing any part quick and simple. Operating instructions indicated on all valve handles and devices make operation safe and easy to comprehend.
Multiple Models and Available Configurations
Our adaptability, in order to better meet our customers' needs, is our main priority.
Available Configurations
Preaction
- Non-interlocked with pneumatic or electric release
- Single interlocked with pneumatic or electric release
- Double interlocked with pneumatic-pneumatic, electric-pneulectric or electric-pneumatic release
Surefire®
- Failsafe single or double interlocked preaction system
Multicycle
- Firecycle® III single or double interlocked preaction
- Firecycle® III deluge
- Firecycle® III wet
Deluge
- With hydraulic, pneumatic or electric release
Dry Pipe
- Available in standard 175 psi or HP 250 psi
Wet Pipe
- Available with constant pressure trim, retard chamber or excess pressure pump
Dimensions of Typical Skid Units
SYSTEM SIZE | A | B | C | D | E | F |
---|---|---|---|---|---|---|
1.5'' | 2" | 1 1/2'' | 2" | 23" | 25" | 38" |
2" | 2" | 2" | 2" | 23" | 25" | 38" |
3" | 4" | 3" | 2" | 36" | 25" | 44" |
4" | 4" | 4" | 2" | 36" | 25" | 48" |
6" | 6" | 6" | 2" | 46" | 25" | 60" |
Note : Dimensions and actual size may vary depending on options and configuration selected, please refer to data sheets for exact dimensions.
Dimensions of Remote-Controlled and Self-Contained Units
SYSTEM SIZE | A | B | C | D | E | F |
---|---|---|---|---|---|---|
1.5'' | 2" | 1 1/2'' | 2" | 23" | 25" | 77" |
2" | 2" | 2" | 2" | 23" | 25" | 77" |
3" | 4" | 3" | 2" | 36" | 25" | 77" |
4" | 4" | 4" | 2" | 36" | 25" | 77" |
6" | 6" | 6" | 2" | 46" | 25" | 77" |
8'' | 8" | 8" | 2" | 54" | 31" | 81" |
Note : Dimensions and actual size may vary depending on options and configuration selected, please refer to data sheets for exact dimensions.
What TOTALPAC 3 units are made of?
FireFlex systems are made of industry-recognized components. We’re proud to work with these amazing partners.
Renowned Control Panel
The Viking VFR-400 is cULus Listed, FM Approved and meets UL 864-9 requirements. It features onboard menu-driven programming with twelve pre-installed programs to facilitate set up.
The panel is compatible with multiple initiating devices such as: linear heat detection, smoke and heat detectors, waterflow indicators, low & high air pressure switches as well as manual pull stations.
Aligned with key NFPA Requirements
We are actively involved in supporting and training the fire protection practitioner at all levels—including industry-related associations such as NFPA, SFPE, AFSA, NFSA and ASPE.
Releasing Circuit Disconnect Switch
Required by NFPA 72 - 2010 Edition, this feature is standard on all our TOTALPAC®3 units and prevents accidental discharge during maintenance or inspection. Operation of the key switch physically disconnects the release circuit wiring and causes a trouble signal at the releasing control panel.
Why trust the FireFlex team and its systems?
Our cutting-edge systems are an alliance between research, development, quality & durability.
BECAUSE WE ARE INDUSTRY PIONEERS
Since its inception in 1991, FIREFLEX SYSTEMS has been designing and manufacturing state-of-the-art innovative integrated fire protection systems that set the benchmark in the market.
FOR THE WIDEST SELECTION AVAILABLE ON THE MARKET
FIREFLEX SYSTEMS offers the widest selection of integrated systems on the market. Regardless of the hazard to be protected, FIREFLEX is able to offer the best available technology with the widest range of options to suit all needs.
FOR OUR QUALITY CONTROL
FIREFLEX SYSTEMS' commitment, year after year, to quality and continuous improvement has resulted in achieving and maintaining its ISO 9001 quality certification. Its modern facilities are geared towards producing a high-volume of quality integrated systems in a factory-controlled setting.
FOR OUR TECHNICAL SUPPORT
Whether it is through exhibits, conferences, lunch & learn presentations, technical seminars, Webinars or one-on-one technical discussions, FIREFLEX's technical sales representatives draw on their in-depth knowledge and expertise to provide a level of technical support that meets or exceeds customer expectations.
FOR OUR CUSTOMER SERVICE
Our customer service department is readily available to address any product related service call, replacement part or general operation and maintenance questions that may arise. All our integrated product lines possess a serial number which is entered into our database. This enables FIREFLEX to record and track service calls, replacement parts, or any system modifications that have been reported on individual units.
FOR OUR INNOVATIVE PRODUCTS
Actively involved with research and development, FIREFLEX embarked on a new endeavor to better serve the fire protection practitioner in addressing challenging fire protection scenarios that evolve in modern life.
Additional Features
Designed with user-friendly features, the TOTALPAC® 3 units are easy to install and maintain.
- cULus & FM Approved as an assembled unit
- Modular Viking conventional trim rated at 250 psi
- Galvanized trim piping standard in all units
- Factory assembled, programmed and tested
- Serial number for easy reference
- Corrosion resistant cabinet with flush type handle and lock
- No open drain cup inside the unit
- Available in 6 sizes: 1½" (40mm), 2" (50mm), 3" (80mm), 4" (100mm), 6" (150mm) and 8" (200 mm)
- Self-contained unit prewired to the Viking VFR-400 releasing control panel
- Failsafe preaction type with a Surefire® trim
- Multicycle units using Firecycle® III technology
- Numerous modular options to meet the most demanding jobsite requirements: anti-column device, flanged inlet & outlet pipes connections, fire department connection outlet, supervised shut-off valve & sight glass
- 4 styles of modular air supply optionsInlet & outlet hydrostatic test ports
- Assembled under ISO 9001 quality control standards User-friendly standardized operation & installation manual
- Free interactive simulator (on-demand)
APPROVALS & STANDARD LISTING
Air Supply for Cabinets
The automatic sprinkler piping is supervised by compressed air from a source installed inside or outside the cabinet. The air supply must be regulated. When the compressor option is selected (air supply style “A”), the motor must be sized to restore normal system air pressure within 30 minutes as per NFPA 13 requirements. Air supply B, C and D are also available options.
Air Supply Style "A"
Riser Shut-off Valve Option
The riser shut-off valve option consists of a supervised butterfly valve which allows for a full flow trip test without flooding the system’s piping and a sight glass located on the main drain for visual indication of the water flow.
Every TOTALPAC 3 Unit configuration meets NFPA requirements and has also been submitted to the authorities where it was subjected to the toughest approval and testing requirements. Every component has been tested and proven by recognized listing laboratories to insure compatibility between each one and their full integration into the final product.
Our modern manufacturing facility allows prefabrication and storage of the most common configurations, making our deliveries the fastest in the industry.
TOTALPAC 3 LISTING & Certificates
The TOTALPAC® 3 units are cULus and FM Approved.
Click on the links below to view the TOTALPAC® 3 certificates:
- cULus Listed (See Certificate)
- CAN-UL Listed (See Certificate)
- FM Approval (See Certificate)
- CSFM (See Certificate)
- NYC Certificate of Approval (See Certificate)
Certifications per type :
- Preaction: cULus, FM
- Deluge: c-UL-us, FM
- Firecycle® III Preaction: c-UL-us, FM, NYC
- Firecycle® III Deluge: c-UL-us, NYC
- Firecycle® III Wet Pipe: c-UL-us, FM, NYC
- Surefiretm Preaction: c-UL-us, FM, NYC
- Dry Pipe: FM
- Dry Pipe (HP®): c-UL-us & FM
- Wet Pipe: c-UL-us & FM
Talk To A Fire Protection Expert
Whether you want to select, specify, install or maintain our systems, you'll find in this section a range of useful documents related to our integrated systems. For further information, do not hesitate to contact our team of experts.