> Home    > Our Integrated Systems > TOTALPAC® X
  • Description
  • Options
  • Documentation

TotalPac X - FireFlexDESIGNED FOR OUTDOOR INSTALLATIONS AND CORROSIVE ENVIRONMENTS. Once again, FireFlex Systems rises to the occasion to address specific industry needs and to provide innovative fire protection solutions adapted for challenging applications. Designed with user-friendly features, the TOTALPAC® X units are easy to install and maintain.

To learn more, click on the topics below.

Features

TotalPac X - FireFlexDesigned with user-friendly features, the TOTALPAC® X units are easy to install and maintain.   

  • Easy and compact installation
  • Wide door for easy access
  • NEMA 3 or NEMA 4 construction
  • Quarter turn door latches
  • Lockable door to protect against tampering
  • Lifting lugs provided for safe and easy handling
  • Corrosion resistant paint finish
  • Water supply connection piped through the bottom center of the unit to avoid freeze-up potential
  • Single drain connection
  • Serial number for easy reference

Cabinets

Factory assembly of the TOTALPAC® X cabinets ensures that all components have been carefully integrated. All systems are fully programmed and tested at the factory which facilitates the onsite installation and commissioning process.

The TOTALPAC® X cabinets are of the freestanding type and are made of robust 14 gauge steel with a corrosion resistant fire red paint finish, polyester powder-coated and oven-baked on a phosphate base. Cabinets are also provided with two locked frontal doors that are removable without special tools, reducing space requirements for ease of installation and maintenance. Furthermore, all doors are provided with a neoprene gasket to reduce vibrations.

Technical details:

  • Compact layout saves floor space
  • Fully tested and programmed at the factory
  • Unique serial number on every unit
  • User-friendly owner's manual with every unit
  • Simplified operation and maintenance
  • Factory built under ISO-9001 conditions

Available Types

Preaction

  • Non-interlocked with pneumatic or electric release
  • Single interlocked with pneumatic or electric release
  • Double interlocked with pneumatic-pneumatic, electric-pneulectric or electric-pneumatic release

Surefire®

  • Failsafe single or double interlocked preaction system

Multicycle

  • Firecycle® III single or double interlocked preaction
  • Firecycle® III deluge
  • Firecycle® III wet

Dry Pipe

  • Available in standard 175 psi or HP 250 psi

Wet Pipe

  • Available with constant pressure trim, retard chamber or excess pressure pump

Construction Nema

The TOTALPAC® X units are NEMA 3X or NEMA 4X stainless steel cabinet construction for corrosive environments.

NEMA 3*
Enclosures constructed for either indoor or outdoor use to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); and that will be undamaged by the external formation of ice on the enclosure.

NEMA 4*
Enclosures constructed for either indoor or outdoor use to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); and that will be undamaged by the external formation of ice on the enclosure.

NEMA 3X*
Enclosures constructed for either indoor or outdoor use to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (falling dirt and windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow); that provides an additional level of protection against corrosion and that will be undamaged by the external formation of ice on the enclosure.

NEMA 4X*
Enclosures constructed for either indoor or outdoor use to provide a degree of protection of the equipment inside the enclosure against ingress of solid foreign objects (windblown dust); to provide a degree of protection with respect to harmful effects on the equipment due to the ingress of water (rain, sleet, snow, splashing water, and hose directed water); that provides an additional level of protection against corrosion; and that will be undamaged by the external formation of ice on the enclosure.

COMPARISON OF SPECIFIC NON-HAZARDOUS APPLICATIONS* (chart)

*Reprinted from NEMA 250-2003 by permission of the National Electrical Manufacturer’s Association.

Our adaptability, in order to better meet our customers' needs, is our main priority. Consequently, here is the available range of options for the TOTALPAC® X units.

Air Supply Options for Cabinets

The automatic sprinkler piping is supervised by compressed air from a source installed inside or outside the cabinet. The air supply must be regulated. When the compressor option is selected (air supply style “A”), the motor must be sized to restore normal system air pressure within 30 minutes as per NFPA 13 requirements.

  1. Air supply style “A”: is used to supervise the sprinkler piping network of dry or preaction systems. This option includes an oilless piston-type air compressor with supervisory trim integrated into the TOTALPAC® X cabinet and factory piped to the system riser.
    Air compressors have open, single-phase motors with internal thermal protection.
  2. Air supply style “B”: is provided with an air pressure maintenance device factory mounted and adjusted in the TOTALPAC® X cabinet and piped to the air inlet port of the unit. Used to supervise the sprinkler piping network of dry or preaction sprinkler systems when the external air supply (by tank-mounted air compressor, plant air or dry nitrogen cylinders) is provided by others.

    Note: the air supply must be restricted to ensure that it cannot replace air as fast as it escapes when a releasing device or sprinkler operates.
  3. Air supply style “C”: is provided with an air pressure maintenance device factory mounted in the TOTALPAC® X cabinet. Used only for the pilot line of a pneumatically operated system.
  4. Air supply style “D”: is provided with an air supervisory switch and shut-off trim. Used for freezer application with external air supply and regulation.

Heater Option

TOTALPAC X HEATER OPTION - FIREFLEXHeater option is recommended where ambient temperature can drop below 40°F (4.5°C). The cabinet’s electric heater temperature cut-out point is set at 50°F (10°C). The heater option is equipped with a low temperature sensor that will activate a supervisory signal when temperature drops below 40°±5°F (4.5°±3°C).

Warning: TOTALPAC® X cabinet is rated to provide freeze protection down to a minimum temperature of 14°F (-10°C).

Shut-off Valve Option

The riser shut-off valve option consists of a supervised butterfly valve which allows for a full flow trip test without flooding the system piping and a sight glass located on the main drain for visual indication of the water flow.

Insulated Enclosure

Insulation is made on foam core 2” thick R13 and have a foil-faced sheathing board composed of a uniform closed cell polyisocyanurate foam core bonded on each side to a triminate foil facer. One side has a foil reflective facer and the other side has a non-reflective foil facer.

Low Temperature Sensor

The low temperature sensor will close the normally open contact when the temperature drops below 40°F (4.5°C).

The sensor will automatically reset to its normal state when the temperature rises above 40°F (4.5°C).

Light Option

TOTALPAC X LIGHT OPTION - FIREFLEX

An optional fluorescent enclosure light is available for all cabinet configurations. A remote door switch activates the light when the door is opened.

 

 Light option can be ordered in two supply voltage settings:

  • 120Vac-60Hz.
  • 220Vac-50Hz.

Here is the TOTALPAC® X full documentation.

For further informations, contact us

AutoCAD® Drawings

Datasheets

User Manuals

Under construction, check back soon

Promotional Leaflet